Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower

  • 1
  • 2
  • 3

Brand Name : Lanshuo

Model Number : LSN-10B

Certification : CE ISO

Place of Origin : China

MOQ : 1 set

Price : USD 3000-4000 / set

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 1000 sets per year

Delivery Time : 5-7 working days after receiving advanced payments

Packaging Details : plywood case / pallet

Type : Closed Type Cooling Tower

Application : cooling industrial machine

Cooling Type : Counter Flow

Material : Galvanized Steel Sheet / Stainless Steel Sheet

Voltage : 380V/3-Phase/50Hz

Weight : 560kg

Cooling Capacity : 60000Kcal/h

Fan power : 0.55kw, one sets

Warranty : 12 months

Contact Now

Industrial Closed Circuit Water Cooling Tower

1. Main features of closed loop water cooling tower:

  • Water cooling plus air cooling ensures the better cooling effect.

Air cooling: The soft water or other liquid circulates in the cooler (made of stainless steel tubes). The heat of the water or other liquid is absorbed by the tubes, and then the heat is discharged outside the tower through the fan at the top.

Water cooling: When the water temperature is too high, that is, exceeds the set temperature, the spray system automatically starts working. The spray pump sprays water on the hot and humid tube wall and forms a water film, which absorbs a large amount of heat by evaporation. Part of the spray water becomes water vapor, which is carried away by the flowing air, and the other water drops in the sump for the next cycle.

  • Soft or purified water is used in the water tank, which can extend the working life of the machine that is cooled.
  • Full closed loop, the inner circulating water is completely isolated from the air, so no evaporation, no water loss, no scaling, no blocking. The operating cost is lower than the open loop cooling tower.
  • No pond is needed. Take less space than open loop water cooling tower.
  • Being able to work 24 hours continuously. Stable operation.

2. Brief Introduction of closed circuit cooling tower:

Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower

The primary use of cooling towers is to remove the heat absorbed in the circulating cooling water system used in power plants, petroleum refineries, petrochemical plants, natural gas processing plants, food processing plants, semi-conductor plants Etc… So Same Cooled Water Can Be Used Again… Which Saves Precious water …The smallest cooling towers are designed to handle water streams of only a few Liters of water per minute supplied in small pipes like those might see in a residence, while the largest cool hundreds of thousands of Liters per minute supplied in pipes as much as 15 feet (about 5 meters) in diameter on a large power plant.

A Cooling Tower is a heat exchange system that removes waste heat from a process system fluid, usually water.Cooling towers are used in both commercial and industrial applications.

Technical Parameters of Water Cooling Tower
Model
LSN-10B
Water Cooling Capacity
60000kcal/h
Cooling Water Flow
8m³/h
Working Voltage
3-phase 380V, 50HZ
Water Outlet Diameter
DN63
Water Inlet Diameter
DN63
Water Replenishing Diameter
DN20
Drain Outlet Diameter
DN20
Fan (power of the generator)
0.37kw*1sets
Spray Pump
Rated Power
0.75kw
Water Flow
12m³/h
Circulating pump
Rated Power
1.5kw
Lift
25m
Flow
10m³/h
Dimension (L*W*H)
2320*1000*2380mm
Weight
560kg

3. Parts of Closed Type Cooling Tower:

  • Coil: Made of high-quality seamless steel / copper pipes. The coil unit are galvanized entirely to improve the corrosion resistance ability and extend the service time. The coils can also be made by SS-304/316L stainless steel or T2 red copper. Maximum pressure of our coils could reach to 32Mpa.
  • Spray Pump: Sealed by top quality rotary no-limited machinery seal, no leaking, long lifecycle, small horse power, large flow volume, low noise and high performance.
  • Fan: Aluminum alloy axis-flow type
  • Casing: SS-304/316L or imported Aluminum-zinc alloy plate.
  • Removable Drift Eliminator: PVC material; Make sure that the water loss rate will be less than 0.005%.
  • Cooling Tower Fill: 100% Original Material PVC Infill, special design with great cooling effect.

4. Cooling Tower Package:

Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower

5. Certificates:

Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling TowerIndustrial Cooling Tower Closed Circuit Counter Flow Water Cooling TowerIndustrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower

6. Related Products:

Induction Heating

Machine

Induction Quenching

Machine

Induction Brazing

Machine

Large Melting Furnce
Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower
Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower

Product Tags:

Industrial Water Cooling Tower

      

Circuit Counter Flow Water Cooling Tower

      
Buy cheap Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower product

Industrial Cooling Tower Closed Circuit Counter Flow Water Cooling Tower Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhengzhou Lanshuo Electronics Co., Ltd
*Subject:
*Message:
Characters Remaining: (0/3000)